Specifications:
Output
Output Power Capacity 12 kW / 15 kVA
Max Configurable Power 12 kW / 15 kVA
Nominal Output Voltage 230V
Efficiency at Full Load 95.5%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 220, 240
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 3-wire (H N + G)
(1) Screw Terminals
Output Voltage Tolerance +/- 5% static and 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.0%
Required Output Current Protection 75A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 20A
Input Breaker Capacity 25 A
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY50K100F
APC Symmetra PX UPS SY50K100F
Specifications:OutputOutput Power Capacity 50 kW / 50 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC Galaxy VM UPS GVMSB225KGS
APC Galaxy VM UPS GVMSB225KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 350ABypass Protection Device 400AOutputOutput Power Capacity 202.5 kW / 225 kVAMax Configurable Power 202.5 kW / 225 kVANominal Output Voltage 480V 3PH
APC Back-UPS BE350G-LM
APC Back-UPS BE350G-LM
Back-UPS specification:Output Frequency (sync to mains) 47 - 63 HzTopology StandbyWaveform Type Stepped approximation to a sinewaveOutput Connections(3) NEMA 5-15R (Battery Backup) NEMA 5-15R(3) NEMA 5-15R (Surge Protection) NEMA 5-15RInputNominal Input Voltage 120VInput Frequency 50/60 Hz +/- 3 Hz
APC MGE Galaxy 5000 UPS SUG540A90UL
APC MGE Galaxy 5000 UPS SUG540A90UL
Specifications:OutputOutput Power Capacity 36 kW / 40 kVAMax Configurable Power 36 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 93.2%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineWaveform Ty
APC Smart-UPS VT SUVTP15KF3B4S
APC Smart-UPS VT SUVTP15KF3B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency (sync t
APC Symmetra UPS SYA12K16PXR
APC Symmetra UPS SYA12K16PXR
Specifications:OutputOutput Power Capacity 9600 Watts / 12 kVAMax Configurable Power 12.8 kW / 16 kVANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 120/208 or 120/240 output voltageOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 63 HzOt
APC MGE Galaxy 3500 UPS G35T15K3I4B4S
APC MGE Galaxy 3500 UPS G35T15K3I4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC Symmetra PX UPS SY400K500D
APC Symmetra PX UPS SY400K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY90K100F
APC Symmetra PX UPS SY90K100F
Specifications:OutputOutput Power Capacity 90 kW / 90 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC MGE Galaxy 3500 UPS G35T15KH4B4S
APC MGE Galaxy 3500 UPS G35T15KH4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync