APC Symmetra PX UPS SY400K500D

APC Symmetra PX UPS SY400K500D
share

Specifications:
General
Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%
Output
Output Power Capacity 400 kW / 400 kVA
Max Configurable Power 500 kW / 500 kVA
Nominal Output Voltage 400V 3PH, 480V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 50 Hz, 60 Hz
Other Output Voltages 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 6% for full non linear load
Overload Operation 10 minutes @ 125% and 30 seconds @ 150%
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH, 480V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 4-wire (3PH + G)
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 340 - 460 (400V), 408 - 552 (480)V
Other Input Voltages 415
Maximum Short Circuit Withstand (Icw) 50.0 kA
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC Symmetra PX UPS SY200K250D
APC Symmetra PX UPS SY200K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 200 kW / 200 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 3500 UPS G35T30KHS
APC MGE Galaxy 3500 UPS G35T30KHS
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.8%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Symmetra PX UPS SY80K100F
APC Symmetra PX UPS SY80K100F
Specifications:OutputOutput Power Capacity 80 kW / 80 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC Smart-UPS SUA5000RMT5U
APC Smart-UPS SUA5000RMT5U
Destribtions:APC Smart-UPS,4000 Watts /5000 VA,Input 208V /Output 208V, Interface Port DB-9 RS-232, SmartSlot, Rack Height 5 UIncludes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, User Manual, Web/SNMP Management CardStandard Lead Time: Usually Ships within 3 We
APC Symmetra PX UPS SY300K500DR-PD
APC Symmetra PX UPS SY300K500DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 300 kW / 300 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS VT SUVTR40KH4B5S
APC Smart-UPS VT SUVTR40KH4B5S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.0%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Back-UPS Pro BR1300G
APC Back-UPS Pro BR1300G
Technical Specification:Output Power Capacity 780 Watts / 1300 VAMax Configurable Power 780 Watts / 1300 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology Line InteractiveWaveform Type Stepped approximation to a sinewaveOutput Connections(5) NEMA 5-15R (Battery B
APC MGE Galaxy 4000 UPS G4TUPS40
APC MGE Galaxy 4000 UPS G4TUPS40
Specifications: General Bypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 111A Output Output Power Capacity 32 kW / 40 kVA Max Configurable Power 32 kW / 40 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0%
APC Smart-UPS VT SUVTR30KH4B5S
APC Smart-UPS VT SUVTR30KH4B5S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.4%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS SURTD5000RMXLP3U
APC Smart-UPS SURTD5000RMXLP3U
Specifications:OutputOutput Power Capacity 4000 Watts / 5000 VAMax Configurable Power 4000 Watts / 5000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 90.0%Output Voltage Distortion Less than 2%Output Frequency (sync t