Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-N03012L

Omron Power Supply S8EX Series S8EX-N03012L

Omron Power Supply S8EX Series S8EX-N03012L
share

With chassis , Input 100 to 240 VAC , 30W , Output 12V 2.5A
Power rating 30 W
Efficiency 82% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz )
Rated input current 0.7 A TYP. ï¼ˆAt 100 VAC input)0.4 A TYP. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 15 A TYP. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))30 A TYP. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 12 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 240 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 2.5 A
Start up time 800 ms TYP. ï¼ˆ100 VAC input)
Hold time 20 ms TYP. ï¼ˆ100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis

Omron S8JX Switch Mode Power S8JX-P05048D
Omron S8JX Switch Mode Power S8JX-P05048D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 48V 1.1A , DIN Rail mounting typePower rating 50 WEfficiency 80% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8JX Switch Mode Power S8JX-P10048C
Omron Power Supply S8JX Switch Mode Power S8JX-P10048C
Covered type , Input 100 to 240 VAC , 100W , Output 48V 2.1A , Front-mounting typePower rating 100 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8TX Series S8TS-02505
Omron Power Supply S8TX Series S8TS-02505
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 5 V 5 APower rating 25 WEfficiency 73% TYP. ï¼ˆAt rated input, 100% load)Rated input voltage 100 to&n
Omron Power Supply S8VS Series S8VS-18024BE
Omron Power Supply S8VS Series S8VS-18024BE
Total Run Time Monitor , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 
Omron Power Supply S8VS Series S8VS-18024A
Omron Power Supply S8VS Series S8VS-18024A
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 180 W , Output 24 V 7.5 APower rating 180 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt&nb
Omron Power Supply S8EX Series S8EX-N03024
Omron Power Supply S8EX Series S8EX-N03024
Open type , Input 100 to 240 VAC , 30W , Output 24V 1.3APower rating 30 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)86% Min. ï¼ˆAt 200 VAC input)Rated inpu
Omron S8JX Switch Mode Power S8JX-G01524D
Omron S8JX Switch Mode Power S8JX-G01524D
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 24V 0.65A , DIN Rail mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltag
Omron Power Supply S8VS Series S8VS-09024A
Omron Power Supply S8VS Series S8VS-09024A
andard Model , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 A , Screwless Terminal BlockPower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)84% TYP.&n
Omron Power Supply S8VM Series S8VM-03005C
Omron Power Supply S8VM Series S8VM-03005C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 30 W , Output 5 V 6 APower rating 30 WEfficiency 75% Min.Rated input voltage 100&nb
Omron S8JX Switch Mode Power S8JX-G05024D
Omron S8JX Switch Mode Power S8JX-G05024D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , DIN Rail mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-inp