Open-Frame Type , Input 100 to 240 VAC , 100W , Output 24V 4.5A , Front-mounting type
Power rating 100 W
Efficiency 83% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz Single-phase)
Rated input current 2.5 A Max. ï¼ˆAt 100 VAC input)1.5 A Max. ï¼ˆAt 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 20 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))40 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +15% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 4.5 A
Start up time 500 ms Max. ï¼ˆUp to 90% of output voltage at rated input and output)
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 175% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 120 to 140 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 7 min)
Overheat protection No
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class AEmission AC mains: Conforms to EN55011 Group 1 Class A and based on FCC Class AEMS: EN61204-3 High severity levels
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 60 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Terminal type Screw terminal
Mounting type Front-mounting typeBottom-mounting typeSide-mounting type
Attachment Front-mounting Bracket
Weight 550 g Max.

Omron Power Supply S8JX Switch Mode Power S8JX-P15012C
Omron Power Supply S8JX Switch Mode Power S8JX-P15012C
Covered type , Input 100 to 240 VAC , 150W , Output 12V 13A , Front-mounting typePower rating 150 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowable-input voltage
Omron Power Supply S8JX Switch Mode Power S8JX-G15012CD
Omron Power Supply S8JX Switch Mode Power S8JX-G15012CD
Covered type , Input 100 to 240 VAC , 150 W , Output 12 V 13 A , DIN Rail mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Covered type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8VS Series S8VS-06024A-F
Omron Power Supply S8VS Series S8VS-06024A-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt 
Omron Power Supply S8EX Series S8EX-N01515
Omron Power Supply S8EX Series S8EX-N01515
Open type , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. ï¼ˆAt 100 VAC input)78% Min. ï¼ˆAt 200 VAC input)Rated input&
Omron Power Supply S8JX Switch Mode Power S8JX-G10048C
Omron Power Supply S8JX Switch Mode Power S8JX-G10048C
Covered type , Input 100 to 240 VAC , 100 W , Output 48 V 2.1 A , Front-mounting typePower rating 100 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable
Omron Power Supply S8VM Series S8VM-05024C
Omron Power Supply S8VM Series S8VM-05024C
Standard Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 24 V 2.2 APower rating 50 WEfficiency 80% Min.Rated input voltage 100
Omron Power Supply S8VM Series S8VM-03024AD
Omron Power Supply S8VM Series S8VM-03024AD
Undervoltage Alarm Type , Covered Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 30 W , Output 24 V 1.3 APower rating 30 WEfficiency 81% Mi
Omron Power Supply S8JX Switch Mode Power S8JX-G15012
Omron Power Supply S8JX Switch Mode Power S8JX-G15012
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 12V 13A , Front-mounting typePower rating 150 WEfficiency 79% Min.Rated input voltage 100 to 240 VACAllowable-input volt
Omron Power Supply S8VS Series S8VS-48024B-F
Omron Power Supply S8VS Series S8VS-48024B-F
Total Run Time Monitor , Input 100 to 240 VAC , 480 W , Output 24 V 20 A , Screwless Terminal BlockPower rating 480 WEfficiency 85% TYP. ï¼ˆAt 100 VAC i