Omron Power Supply S8JX Switch Mode Power S8JX-P30005CD

Omron Power Supply S8JX Switch Mode Power S8JX-P30005CD
share

Covered type , Input 100 to 240 VAC , 300W , Output 5V 60A , DIN Rail mounting type
Power rating 300 W
Efficiency 75% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 4.5 A Max. ï¼ˆAt 100 VAC input)2.2 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min.
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 5 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 3%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max.
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 60 A
Start up time 1000 ms Max.
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection YesResetting: Reset the power by turning it back (OFF time: at least 3 min)
Parallel operation Yes (Up to 5 Blocks)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL UR: UL508 (Recognition), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class B
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0706 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 100 mA)Between all outputs and RC terminals: 100 VAC for 1 min (Detection current: 100 mA)Between all outputs and ALM terminals: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Heat radiation Forced air-cooling
Construction Covered type
Terminal type Screw terminal

Omron S8JX Switch Mode Power S8JX-G01512
Omron S8JX Switch Mode Power S8JX-G01512
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 12V 1.3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron S8JX Switch Mode Power S8JX-G01548
Omron S8JX Switch Mode Power S8JX-G01548
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 48V 0.35A , Front-mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input voltage 100 to
Omron Power Supply S82S S82S-7705
Omron Power Supply S82S S82S-7705
Input 12 to 24 VDC , 7.5 W , Output 5 V 1.5 APower rating 7.5 WEfficiency 66% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6 
Omron Power Supply S8TX Series S8TS-06024-E1
Omron Power Supply S8TX Series S8TS-06024-E1
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 24 V 2.5 APower rating 60 WEfficiency 80% TYP. ï¼ˆAt rated input, 100% load)Rated input voltage 100 t
Omron Power Supply S8VM Series S8VM-10024A
Omron Power Supply S8VM Series S8VM-10024A
Undervoltage Alarm Type , Covered Type , Bottom Mounting Type , Input 100 to 240 VAC , 100 W , Output 24 V 4.5 APower rating 100 WEfficiency 82% Min.Rated input
Omron S8JX Switch Mode Power S8JX-G05024
Omron S8JX Switch Mode Power S8JX-G05024
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 24V 2.1A , Front-mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8VS Series S8VS-48024B-F
Omron Power Supply S8VS Series S8VS-48024B-F
Total Run Time Monitor , Input 100 to 240 VAC , 480 W , Output 24 V 20 A , Screwless Terminal BlockPower rating 480 WEfficiency 85% TYP. ï¼ˆAt 100 VAC i
Omron S8JX Switch Mode Power S8JX-G03515CD
Omron S8JX Switch Mode Power S8JX-G03515CD
Covered type , Input 100 to 240 VAC , 35 W , Output 15 V 2.4 A , DIN Rail mounting typeAs of November 15, 2012Power rating 35 WEfficiency 73% Min.Rated inp
Omron Power Supply S8EX Series S8EX-BP15048
Omron Power Supply S8EX Series S8EX-BP15048
Open type , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)88% Min. ï¼ˆAt 200 VAC input)Rated in
Omron Power Supply S8JX Switch Mode Power S8JX-G10005D
Omron Power Supply S8JX Switch Mode Power S8JX-G10005D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp