Specifications:
Topology Online Double Conversion
Power Rating (VA) 3000
Rated Load Capacity (Watts) 2500
Electrical Input
Input Voltage 208-240 neutral required
Input Connection L14-30P L14-30P
Electrical Output
Output Voltage 208-240/120
Output Connection
(1) L14-30R L14-30R (1) L6-30R L6-30R
(4) 5-20R 5-20R
Physical Dimensions
Dimensions H x W x D (inches) 19.5 x 17 x 25.5

Powerware BPIII 300 Industrial UPS 225-300 kVA
Powerware BPIII 300 Industrial UPS 225-300 kVA
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than
Powerware BPII HE UPS 10 kVA/8 kw
Powerware BPII HE UPS 10 kVA/8 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware Plus18 UPS Model 12
Powerware Plus18 UPS Model 12
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 3% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load)Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl
Powerware 9125 UPS PW9125 2000 20R
Powerware 9125 UPS PW9125 2000 20R
Descriptions:the Powerware 9125 UPS delivers the ultimate in protection,truly isolating your equipment from all nine of the commonpower anomalies lurking in public utility power. Availableas either a rackmount or stand-alone unit, the compactand elegant 9125 supplies continuous, conditioned powerto
Powerware 9125 UPS PW9125 3000
Powerware 9125 UPS PW9125 3000
Descriptions:the Powerware 9125 UPS delivers the ultimate in protection,truly isolating your equipment from all nine of the commonpower anomalies lurking in public utility power. Availableas either a rackmount or stand-alone unit, the compactand elegant 9125 supplies continuous, conditioned powerto
Powerware 9305 UPS PW9305-40I-NX
Powerware 9305 UPS PW9305-40I-NX
Specifications:Rating 40 kVA Capacity (VA/Watts) 40 kVA/28 kWDimensions WxDxH (mm) 520x788x1530Weight (kg) 230 Input connection Hardwired Output connection HardwiredTypical runtime (Full load) 10 min (Half load) 25 min
Powerware 5119 UPS PW5119 1000
Powerware 5119 UPS PW5119 1000
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Powerware 5119 Rackmount UPS PW5119 2400iRM
Powerware 5119 Rackmount UPS PW5119 2400iRM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware 9 Prestige UPS Model 1000VA/700W
Powerware 9 Prestige UPS Model 1000VA/700W
Specifications: Rating: 650-6000 VA Input Voltage: 120 Vac; 200–240 Vac Output Voltage: 120 Vac; 120/208 120/240 Vac Frequency: 50/60 Hz Configuration: Modular; rack-mount and cabinet
Powerware Plus36 UPS Model 24
Powerware Plus36 UPS Model 24
Specifications: Input Frequency Range 45-65 Hz Power Factor 0.95 Typical at full load Output Voltage Regulation Better than +/- 2% Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load) Transient Response Less than 5% for 100% load, step full recovery within 1/4 cycl