Specifications
INPUT
Rated power 160000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance + 20% - 25%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0,99
Input current 226 A
Current distorsion <3%
Soft start 0-100% in 10
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Rated current 226 A
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 160000 VA
Active power 144000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load <1%
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Inverter efficiency at rated load 95 %
Overload 125% 150% 200% of the rated current for 10' / 1' / 7

Riello Master HP UL UPS MHT UL 125
Riello Master HP UL UPS MHT UL 125
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)125/112.5 %Input voltage distoration (THDi) <3 Out
Riello Multi Sentry UPS MST 120
Riello Multi Sentry UPS MST 120
Specifications:INPUTRated power 120000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Specifications:INPUTRated power 6500 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Net Power UPS NPW 800
Riello Net Power UPS NPW 800
Specifications:INPUTVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 26%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 800 VAActive power 480 WWave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 0.5%)BATTERIESType Maintenance-free sealed le
Riello Master HE UPS MHE 120
Riello Master HE UPS MHE 120
Specifications: INPUT Rated power 120000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 169 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Master HE UPS MHE 300
Riello Master HE UPS MHE 300
Specifications: INPUT Rated power 300000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 423 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t
Riello Multi Sentry UPS MST 15
Riello Multi Sentry UPS MST 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Power Green UPS SPH 10 ER
Riello Sentinel Power Green UPS SPH 10 ER
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform Sinusoidal
Riello Sentinel Power Green UPS SPH 8
Riello Sentinel Power Green UPS SPH 8
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 8000 VAActive power 7200 WWaveform SinusoidalOVERLOAD TIMES
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Riello Sentinel Dual (Low Power) UPS SDH 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency