Specifications:
INPUT
Rated power 60000 VA
Voltage 400 Vac three-phase Vac
Voltage tolerance ± 20%
Frequency 50/60 Hz with autorange
Frequency tolerance 45/65 Hz
Power factor 0.93
Current distorsion <5%
Soft start 0-100% in 10"
BY PASS
Rated voltage 400 Vac three-phase selectable 380 and 415
Voltage tolerance ± 15% (selectable from ± 10% to ± 25% from front panel)
Rated frequency 50/60 Hz (autorange)
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Number phases 3
Back-feed protection yes
Overload capacity Inx10ms 14
OUTPUT and INVERTER OUTPUT
Rated power 60000 VA
Active power 48000 W
Number phases 3 + N
Crest factor (Ipeak/Irms) 3 : 1
Waveform Sinewave
Static stability ± 1%
Dynamic stability ± 5% in 5 ms
Frequency same as the input (autorange)
Voltage distortion with distorcing load <3%
Voltage distortion with linear load 1% (rated) 2% (max)
Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5% from front panel) with mains supply present
Inverter efficiency at rated load 95% %
Overload 125% 150% 200% of the rated current for 10^ / 1^ / 7§

Riello Sentinel Power Green UPS SPH 10
Riello Sentinel Power Green UPS SPH 10
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform SinusoidalOVERLOAD TIME
Riello Master HP UPS MHT 400
Riello Master HP UPS MHT 400
SpecificationsINPUTRated power 400000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 564 ACurrent distorsion
Riello Sentinel Power Green UPS SPH 10 ER
Riello Sentinel Power Green UPS SPH 10 ER
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform Sinusoidal
Riello Master MPS UPS MPM 30
Riello Master MPS UPS MPM 30
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Riello Sentinel Dual (High Power) UPS SDL 6500 TM
Specifications:INPUTRated power 6500 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Vision Dual UPS VSD 2200
Riello Vision Dual UPS VSD 2200
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1980 W Number phases 1 Crest factor (Ipea
Riello Sentinel Dual (High Power) UPS SDL 4000
Riello Sentinel Dual (High Power) UPS SDL 4000
Specifications:INPUTRated power 4000 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Dialog Vision UPS DVR 1100
Riello Dialog Vision UPS DVR 1100
Specifications: INPUT Rated power 1100 VA Voltage 230 Vac Frequency 50/60 Hz with autorange Frequency tolerance ± 10Hz OUTPUT and INVERTER OUTPUT Rated power 1100 VA Active power 740 W Number phases 1 Waveform Sinewave Frequency 50 or 60 Hz with autorange BATTERIES Type Maintenance-fre
Riello Net Power UPS NPW 1500
Riello Net Power UPS NPW 1500
Specifications:INPUTRated power 1500 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 26%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 1500 VAActive power 900 WWave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 0.5%)BATTERIESType Mainte