Specifications:
Output
Output Power Capacity 8000 Watts / 10 kVA
Max Configurable Power 8000 Watts / 10 kVA
Nominal Output Voltage 400V 3PH
Output Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage
Efficiency at Full Load 95.7%
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal
Other Output Voltages 380, 415
Crest Factor Unlimited
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 4-wire (3PH + G)
(1) Hard Wire 5-wire (3PH + N + G)
(1) Screw Terminals
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 5% for full non linear load
Overload Operation 10 minutes @ 125% and 60 seconds @ 150%
Efficiency at Half Load 95.2%
Required Output Current Protection 16A
Bypass Built-in Maintenance Bypass, Built-in Static Bypass
Input
Nominal Input Voltage 400V 3PH
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 304 - 477V
Input voltage adjustable range for mains operation 340 - 460 (400V)V
Other Input Voltages 380, 415
Maximum Input Current 14A
Input Breaker Capacity 16 A
Input Total Harmonic Distortion Less than 5% for full load
Type of Input Protection Required 3-pole breaker

APC MGE Galaxy 3500 UPS G35T15KF4B4S
APC MGE Galaxy 3500 UPS G35T15KF4B4S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
APC Symmetra PX UPS SY64K160H-NB
APC Symmetra PX UPS SY64K160H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 64 kW / 64 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra PX UPS SY30K100F
APC Symmetra PX UPS SY30K100F
Specifications:OutputOutput Power Capacity 30 kW / 30 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutput
APC Symmetra PX UPS SY100K250D
APC Symmetra PX UPS SY100K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 100 kW / 100 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Back-UPS BX650CI-LM
APC Back-UPS BX650CI-LM
Back-UPS specification:Output Power Capacity 390 Watts / 650 VAMax Configurable Power 390 Watts / 650 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50 Hz, 60 HzTopology Line InteractiveWaveform Type Stepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (Battery Backup)
APC Smart-UPS SUA2200RM2U
APC Smart-UPS SUA2200RM2U
Destribtions:APC Smart-UPS,1980 Watts /2200 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlot, USB, Rack Height 2 UIncludes: CD with software, Rack Mounting support rails, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usually in Stock
APC Galaxy VM UPS GVMSB160KGS
APC Galaxy VM UPS GVMSB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC Smart-UPS SUM3000RMXL2U
APC Smart-UPS SUM3000RMXL2U
Specifications:OutputOutput Power Capacity 2850 Watts / 3000 VAMax Configurable Power 2850 Watts / 3000 VANominal Output Voltage 120VEfficiency at Full Load 95.0%Topology Line InteractiveOutput Connections(6) NEMA 5-15R NEMA 5-15R(2) NEMA 5-20R NEMA 5-20RBypass Internal Bypass (Automatic and Manual)
APC Symmetra PX UPS SY64K160H-PD
APC Symmetra PX UPS SY64K160H-PD
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 64 kW / 64 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra PX UPS SY100K250DR-PD
APC Symmetra PX UPS SY100K250DR-PD
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 100 kW / 100 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out