Specifications:Output
Output Power Capacity 12 kW / 15 kVA
Max Configurable Power 12 kW / 15 kVA
Nominal Output Voltage 120V, 208V
Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage
Output Voltage Distortion Less than 5%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages 220, 240
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 3-wire (2PH + G)
(12) NEMA 5-20R NEMA 5-20R
(4) NEMA L6-20R NEMA L6-20R
(1) NEMA L6-30R NEMA L6-30R
Overload Operation 60 seconds @ 125% and 30 seconds @ 150%
Bypass Built-in Static Bypass, Internal Bypass (Automatic and Manual), Optional External Bypass
Input
Nominal Input Voltage 208V
Input Frequency 40 - 70 Hz (auto sensing)
Input Connections
Hard Wire 3-wire (2PH + G)
Input voltage range for main operations 160 - 280V
Other Input Voltages 240
Maximum Input Current 83A
Input Breaker Capacity 100 A
Input Total Harmonic Distortion Less than 5% for full load

APC Symmetra PX UPS SY400K500D
APC Symmetra PX UPS SY400K500D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 400 kW / 400 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY64K160H-NB
APC Symmetra PX UPS SY64K160H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 64 kW / 64 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC Symmetra UPS SYH4K6RMT-TF3
APC Symmetra UPS SYH4K6RMT-TF3
Specifications:OutputOutput Power Capacity 2800 Watts / 4000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 85.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
APC Symmetra UPS SYH2K6RMT
APC Symmetra UPS SYH2K6RMT
Specifications:OutputOutput Power Capacity 1400 Watts / 2000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 91.0%Output Voltage Distortion Less than 5% at full loadOutput Frequency
APC MGE Galaxy 4000 UPS G4TUPS50
APC MGE Galaxy 4000 UPS G4TUPS50
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 139A Output Output Power Capacity 40 kW / 50 kVA Max Configurable Power 40 kW / 50 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0% Output Voltage Disto
APC Symmetra PX UPS SY150K250D
APC Symmetra PX UPS SY150K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 150 kW / 150 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC MGE Galaxy 3500 UPS G35T40K3I4B4S
APC MGE Galaxy 3500 UPS G35T40K3I4B4S
Specifications:OutputOutput Power Capacity 32 kW / 40 kVAMax Configurable Power 32 kW / 40 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.4%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC Smart-UPS SUM1500RMXL2U
APC Smart-UPS SUM1500RMXL2U
Specifications:OutputOutput Power Capacity 1425 Watts / 1440 VAMax Configurable Power 1425 Watts / 1440 VANominal Output Voltage 120VTopology Line InteractiveOutput Connections(8) NEMA 5-15R NEMA 5-15RBypass Internal Bypass (Automatic and Manual)InputNominal Input Voltage 120VInput Frequency 50/60 H
APC Smart-UPS VT SUVTSBP20K30F
APC Smart-UPS VT SUVTSBP20K30F
Specifications:OutputNominal Output Voltage 208V 3PHInputNominal Input Voltage 208V 3PHInput Frequency 60 HzPhysicalNet Weight 127.00 KGMaximum Height 1487.00 mmMaximum Width 352.00 mmMaximum Depth 837.00 mmShipping Weight 156.00 KGShipping Height 1663.00 mmShipping Width 723.00 mmShipping Depth 110
APC Symmetra PX UPS SY96K160H-NB
APC Symmetra PX UPS SY96K160H-NB
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase