Back-UPS specification:Output Frequency (sync to mains) 47 - 63 Hz
Topology Standby
Waveform Type Stepped approximation to a sinewave
Output Connections
(3) NEMA 5-15R (Battery Backup) NEMA 5-15R
(3) NEMA 5-15R (Surge Protection) NEMA 5-15R
Input
Nominal Input Voltage 120V
Input Frequency 50/60 Hz +/- 3 Hz (auto sensing)
Input Connections
NEMA 5-15P NEMA 5-15P
Cord Length 1.52 meters
Input voltage range for main operations 88 - 139V
Batteries & Runtime
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Typical recharge time 16 hour(s)
Replacement Battery RBC35
RBC™ Quantity 1

APC Smart-UPS SURTD3000RMXLT3U
APC Smart-UPS SURTD3000RMXLT3U
Specifications:OutputOutput Power Capacity 2100 Watts / 3000 VAMax Configurable Power 2100 Watts / 3000 VANominal Output Voltage 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 92.0%Output Voltage Distortion Less than 3%Output Frequency (sync to main
APC MGE EPS 8000 UPS E8TUPS625
APC MGE EPS 8000 UPS E8TUPS625
Specifications:GeneralBypass Connection 4 wire (3Ph + N) or 5 wire (3Ph + N + G)Bypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 950AOutputOutput Power Capacity 562 kW / 625 kVAMax Configurable Power 562 kW / 625 kVANominal Output Voltage 480V 3PH, 600V 3PHOutpu
APC Symmetra PX UPS SY125K250D
APC Symmetra PX UPS SY125K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 125 kW / 125 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS VT SUVTP30KH4B4S
APC Smart-UPS VT SUVTP30KH4B4S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 96.4%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC MGE Galaxy 3500 UPS G35T20KH2B4S
APC MGE Galaxy 3500 UPS G35T20KH2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.5%Output Voltage Distortion Less than 5%Output Frequency (sync
APC Smart-UPS VT SUVTP10KF4B4S
APC Smart-UPS VT SUVTP10KF4B4S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequen
APC MGE Galaxy 3500 UPS G35T20K3I2B4S
APC MGE Galaxy 3500 UPS G35T20K3I2B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5%Output Frequency (sync to mains) 47
APC Back-UPS Pro BR1000G
APC Back-UPS Pro BR1000G
Technical Specification:OutputOutput Power Capacity 600 Watts / 1000 VAMax Configurable Power 600 Watts / 1000 VANominal Output Voltage 120VOutput Frequency (sync to mains) 50/60Hz +/- 3 HzTopology Line InteractiveWaveform Type Stepped approximation to a sinewaveOutput Connections(4) NEMA 5-15R (Bat
APC Smart-UPS SUA1000
APC Smart-UPS SUA1000
Destribtions:APC Smart-UPS,670 Watts /1000 VA,Input 120V /Output 120V, Interface Port DB-9 RS-232, SmartSlot, USBIncludes: CD with software, Smart UPS signalling RS-232 cable, USB cable, User ManualStandard Lead Time: Usually in Stock
APC Smart-UPS VT SUVTP20KH2B2S
APC Smart-UPS VT SUVTP20KH2B2S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr