Categories
- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
Contact Us
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Home / Products / UPS Power Supply / APC UPS Power Supply / APC Symmetra PX UPS / APC Symmetra PX UPS SY40K100F
APC Symmetra PX UPS SY40K100F
share
Specifications:
Output
Output Power Capacity 40 kW / 40 kVA
Max Configurable Power 100 kW / 100 kVA
Nominal Output Voltage 120V, 208V, 208V 3PH
Output Voltage Distortion Less than 2%
Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominal
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Output Voltage THD < 2% for 0 to 100% linear load and < 6% for full non linear load
Bypass Built-in Static Bypass
Input
Nominal Input Voltage 208V 3PH
Input Frequency 40 - 70 Hz
Input voltage range for main operations 177 - 239 (208V)V
Maximum Input Current 332A
Input Total Harmonic Distortion Less than 5% for full load
APC Symmetra UPS SYH4K6RMT-P1
Specifications:OutputOutput Power Capacity 2800 Watts / 4000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 85.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
Specifications:OutputOutput Power Capacity 2800 Watts / 4000 VAMax Configurable Power 4200 Watts / 6000 VANominal Output Voltage 120V, 208VOutput Voltage Note Configurable for 208 or 240 nominal output voltageEfficiency at Full Load 85.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
APC MGE Galaxy 4000 UPS G4TUPS50
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 139A Output Output Power Capacity 40 kW / 50 kVA Max Configurable Power 40 kW / 50 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0% Output Voltage Disto
Specifications: General Bypass Connection 5 wire (3PH + N + G) Bypass Voltage Tolerance +/- 15% Max Bypass Input Current 139A Output Output Power Capacity 40 kW / 50 kVA Max Configurable Power 40 kW / 50 kVA Nominal Output Voltage 208V 3PH Efficiency at Full Load 89.0% Output Voltage Disto
APC Back-UPS BX650CI-LM
Back-UPS specification:Output Power Capacity 320 Watts / 575 VAMax Configurable Power 320 Watts / 575 VANominal Output Voltage 120VEfficiency at Full Load 70.0%Output Frequency (sync to mains) 50/60 Hz +/-1 HzTopology Line InteractiveWaveform Type Square waveOutput Connections(2) NEMA 5-15R (Surge P
Back-UPS specification:Output Power Capacity 320 Watts / 575 VAMax Configurable Power 320 Watts / 575 VANominal Output Voltage 120VEfficiency at Full Load 70.0%Output Frequency (sync to mains) 50/60 Hz +/-1 HzTopology Line InteractiveWaveform Type Square waveOutput Connections(2) NEMA 5-15R (Surge P
APC Smart-UPS SUM3000RMXLI2U
Specifications:OutputOutput Power Capacity 2850 Watts / 3000 VAMax Configurable Power 2850 Watts / 3000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
Specifications:OutputOutput Power Capacity 2850 Watts / 3000 VAMax Configurable Power 2850 Watts / 3000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageEfficiency at Full Load 95.0%Output Voltage Distortion Less than 5% at full loadOutput Freq
APC Symmetra PX UPS SY150K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 150 kW / 150 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 150 kW / 150 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Smart-UPS SURTA1500RMXL2U
Specifications:OutputOutput Power Capacity 1050 Watts / 1500 VAMax Configurable Power 1050 Watts / 1500 VANominal Output Voltage 120VOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Crest Factor 3 : 1Topology Double Conversion OnlineWave
Specifications:OutputOutput Power Capacity 1050 Watts / 1500 VAMax Configurable Power 1050 Watts / 1500 VANominal Output Voltage 120VOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1Crest Factor 3 : 1Topology Double Conversion OnlineWave
APC MGE Galaxy 5000 UPS SUG580S90UL
Specifications:OutputOutput Power Capacity 72 kW / 80 kVAMax Configurable Power 72 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 92.8%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineWaveform Ty
Specifications:OutputOutput Power Capacity 72 kW / 80 kVAMax Configurable Power 72 kW / 0 VANominal Output Voltage 480V 3PH, 600V 3PHEfficiency at Full Load 92.8%Output Voltage Distortion Less than 2%Output Frequency (sync to mains) 60 HzCrest Factor 3 : 1Topology Double Conversion OnlineWaveform Ty
APC Smart-UPS SURT8000XLI
Specifications:OutputOutput Power Capacity 6400 Watts / 8000 VAMax Configurable Power 6400 Watts / 8000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz us
Specifications:OutputOutput Power Capacity 6400 Watts / 8000 VAMax Configurable Power 6400 Watts / 8000 VANominal Output Voltage 230VOutput Voltage Note Configurable for 220 : 230 or 240 nominal output voltageOutput Voltage Distortion Less than 3%Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz us
APC Symmetra PX UPS SY96K160H
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Max Bypass Input Current 250ABypass Protection Device 250AOutputOutput Power Capacity 96 kW / 96 kVAMax Configurable Power 160 kW / 160 kVANominal Output Voltage 230V, 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase
APC MGE Galaxy 4000 UPS G4TUPS65
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
Hot Products