APC MGE Galaxy 4000 UPS G4TUPS75

APC MGE Galaxy 4000 UPS G4TUPS75
share

Specifications:
General
Bypass Connection 5 wire (3PH + N + G)
Bypass Voltage Tolerance +/- 15%
Max Bypass Input Current 208A
Output
Output Power Capacity 60 kW / 75 kVA
Max Configurable Power 60 kW / 75 kVA
Nominal Output Voltage 208V 3PH
Efficiency at Full Load 87.4%
Output Voltage Distortion Less than 3%
Output Frequency (sync to mains) 60 Hz
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections
(1) Hard Wire 5-wire (3PH + N + G)
Output Voltage Tolerance +/-1% static and +/- 5% at 100% load step
Overload Operation 60 seconds @ 130% and 30 seconds @ 145%
Efficiency at Half Load 87.7%
Required Output Current Protection 208A
Bypass Built-in Bypass
Input
Nominal Input Voltage 208V 3PH
Input Frequency 50/60 Hz
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations 166 - 239V
Maximum Input Current 225A
Input Total Harmonic Distortion Less than 3% for full load
Type of Input Protection Required 3-pole breaker

APC Smart-UPS VT SUVTRT30KF4B5S
APC Smart-UPS VT SUVTRT30KF4B5S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full lo
APC Symmetra PX UPS SY200K250D
APC Symmetra PX UPS SY200K250D
Specifications:GeneralBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%OutputOutput Power Capacity 200 kW / 200 kVAMax Configurable Power 500 kW / 500 kVANominal Output Voltage 400V 3PH, 480V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 50 Hz, 60 HzOther Out
APC Symmetra PX UPS SY100K100F
APC Symmetra PX UPS SY100K100F
Specifications:OutputOutput Power Capacity 100 kW / 100 kVAMax Configurable Power 100 kW / 100 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Distortion Less than 2%Output Frequency (sync to mains) 57 - 63 Hz for 60 Hz nominalTopology Double Conversion OnlineWaveform Type Sine waveOutp
APC Galaxy VM UPS GVMSB160KGS
APC Galaxy VM UPS GVMSB160KGS
Specifications:GeneralBypass Connection Built-in Static BypassBypass Voltage Tolerance +/-10% settable from +/-4/6/8 and 10%Max Bypass Input Current 217ABypass Protection Device 400AOutputOutput Power Capacity 144 kW / 160 kVAMax Configurable Power 144 kW / 160 kVANominal Output Voltage 480V 3PHOutp
APC MGE Galaxy 4000 UPS G4TUPS65
APC MGE Galaxy 4000 UPS G4TUPS65
Specifications:GeneralBypass Connection 5 wire (3PH + N + G)Bypass Voltage Tolerance +/- 15%Max Bypass Input Current 180AOutputOutput Power Capacity 52 kW / 65 kVAMax Configurable Power 52 kW / 65 kVANominal Output Voltage 208V 3PHEfficiency at Full Load 87.4%Output Voltage Distortion Less than 3%Ou
APC Smart-UPS VT SUVTP10KF2B2S
APC Smart-UPS VT SUVTP10KF2B2S
Specifications:OutputOutput Power Capacity 8000 Watts / 10 kVAMax Configurable Power 8000 Watts / 10 kVANominal Output Voltage 120V, 208V, 208V 3PHOutput Voltage Note Configurable for 208 and 220V - 3 PhaseEfficiency at Full Load 93.0%Output Voltage Distortion Less than 5% at full loadOutput Frequen
APC Smart-UPS VT SUVTP15KH2B2S
APC Smart-UPS VT SUVTP15KH2B2S
Specifications:OutputOutput Power Capacity 12 kW / 15 kVAMax Configurable Power 12 kW / 15 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.7%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC MGE Galaxy 3500 UPS G35T30KF4B4S
APC MGE Galaxy 3500 UPS G35T30KF4B4S
Specifications:OutputOutput Power Capacity 24 kW / 30 kVAMax Configurable Power 24 kW / 30 kVANominal Output Voltage 208V 3PHOutput Voltage Note Configurable for 200 : 208 or 220V 3 Phase nominal output voltageEfficiency at Full Load 93.1%Output Voltage Distortion Less than 3%Output Frequency (sync
APC Smart-UPS VT SUVTP20KH4B4S
APC Smart-UPS VT SUVTP20KH4B4S
Specifications:OutputOutput Power Capacity 16 kW / 20 kVAMax Configurable Power 16 kW / 20 kVANominal Output Voltage 400V 3PHOutput Voltage Note Configurable for 380 : 400 or 415 V 3 Phase nominal output voltageEfficiency at Full Load 95.3%Output Voltage Distortion Less than 5% at full loadOutput Fr
APC Smart-UPS SUA3000RM2U
APC Smart-UPS SUA3000RM2U
Smart-UPS specification:OutputOutput Power Capacity 2700 Watts / 3000 VAMax Configurable Power 2700 Watts / 3000 VANominal Output Voltage 110V, 120VOutput Voltage Distortion Less than 5% at full loadOutput Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominalTopology L