Omron Power Supply S8EX Series S8EX-N03024LC-Power Supply, Battery and Inverter
 
Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8EX / Omron Power Supply S8EX Series S8EX-N03024LC

Omron Power Supply S8EX Series S8EX-N03024LC

Omron Power Supply S8EX Series S8EX-N03024LC
share

With chassis and cover , Input 100 to 240 VAC , 30W , Output 24V 1.3A
Power rating 30 W
Efficiency 85% Min. Ã¯Â¼Ë†At 100 VAC input)86% Min. Ã¯Â¼Ë†At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC120 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz )
Rated input current 0.7 A TYP. Ã¯Â¼Ë†At 100 VAC input)0.4 A TYP. Ã¯Â¼Ë†At 200 VAC input)
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 15 A TYP. Ã¯Â¼Ë†At 100 VAC input (For cold start at 25 CEL))30 A TYP. Ã¯Â¼Ë†At 200 VAC input (For cold start at 25 CEL))
Rated output voltage 24 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 480 mV Max.
Static input variation influence 0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 1.5% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 1.3 A
Start up time 800 ms TYP. Ã¯Â¼Ë†100 VAC input)
Hold time 20 ms TYP. Ã¯Â¼Ë†100 VAC input)
Overload protection 105% to 160% of the rated output currentVoltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Power factor improvement function No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B
Applicable standard(SEMI) F47-0706 (200 VAC input)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min.
Vibration resistance 10 to 55 Hz, 19.6 m/s**2 (2 G) in each 3 directions for 1 hour
Shock resistance 196.1 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction With chassis and cover

Omron Power Supply S8VM Series S8VM-05012D
Omron Power Supply S8VM Series S8VM-05012D
Standard Type , Open-Frame Type , DIN Rail Mounting Bracket Type , Input 100 to 240 VAC , 50 W , Output 12 V 4.3 APower rating 50 WEfficiency 79% Min.Rated 
Omron S8JX Switch Mode Power S8JX-G01515CD
Omron S8JX Switch Mode Power S8JX-G01515CD
Covered type , Input 100 to 240 VAC , 15 W , Output 15 V 1 A , DIN Rail mounting typeAs of November 15, 2012Power rating 15 WEfficiency 68% Min.Rated input
Omron Power Supply S8VS Series S8VS-09024-F
Omron Power Supply S8VS Series S8VS-09024-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. Ã¯Â¼Ë†At 100 VAC input)85% TYP. Ã¯Â¼Ë†At&nbs
Omron Power Supply S8JX Switch Mode Power S8JX-G10005D
Omron Power Supply S8JX Switch Mode Power S8JX-G10005D
Open-Frame Type , Input 100 to 240 VAC , 100W , Output 5V 20A , DIN Rail mounting typePower rating 100 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron Power Supply S8JX Switch Mode Power S8JX-G15005CD
Omron Power Supply S8JX Switch Mode Power S8JX-G15005CD
Covered type , Input Switchable between 100 to 120 VAC and 200 to 240 VAC , 150 W , Output 5 V 30 A , DIN Rail mounting typePower rating 150 WEfficien
Omron Power Supply S82S S82S-7712
Omron Power Supply S82S S82S-7712
Input 12 to 24 VDC , 7.5 W , Output 12 V 0.6 APower rating 7.5 WEfficiency 69% Min.Rated input voltage 12 to 24 VDCAllowable-input voltage variable range 10.2 to 27.6&nbs
Omron Power Supply S8VS Series S8VS-01512
Omron Power Supply S8VS Series S8VS-01512
Total Run Time Monitor , Input 100 to 240 VAC , 120 W , Output 24 V 5 A , With Undervoltage Alarm (Ttransistor (Sourcing))Power rating 120 WEfficiency 83% TYP. 
Omron Power Supply S8EX Series S8EX-N01515LC
Omron Power Supply S8EX Series S8EX-N01515LC
With chassis and cover , Input 100 to 240 VAC , 15W , Output 15V 1APower rating 15 WEfficiency 80% Min. Ã¯Â¼Ë†At 100 VAC input)78% Min. Ã¯Â¼Ë†At 200 VAC inputÃ
Omron Power Supply S8JX Switch Mode Power S8JX-P15024D
Omron Power Supply S8JX Switch Mode Power S8JX-P15024D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 24V 6.5A , DIN Rail mounting typePower rating 150 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8JX Switch Mode Power S8JX-P15048CD
Omron Power Supply S8JX Switch Mode Power S8JX-P15048CD
Covered type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , DIN Rail mounting typePower rating 150 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-inpu