Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Omron Power Supply / S8JX Switch Mode Power / Omron Power Supply S8JX Switch Mode Power S8JX-P10048CD

Omron Power Supply S8JX Switch Mode Power S8JX-P10048CD

Omron Power Supply S8JX Switch Mode Power S8JX-P10048CD
share

Covered type , Input 100 to 240 VAC , 100W , Output 48V 2.1A , DIN Rail mounting type
Power rating 100 W
Efficiency 81% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 1.4 A Max. ï¼ˆAt 100 VAC input)0.75 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.9 Min.
Harmonic Current EN61000-3-2
Leakage current 0.5 mA Max. (At 100 VAC input)1 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 48 VDC
Output voltage variable range -10 to +10% (With V. ADJ)(If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
Static input variation influence 0.4% Max. (with AC input voltage)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.05 %/CEL Max. (At rated input/output voltage)
Rated output current 2.1 A
Start up time 1000 ms Max.
Hold time 20 ms Min. (At rated input voltage: 100 or 200 VAC at 100% load.)
Overload protection 105% to 160% of the rated output currentVoltage drop, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Applicable standard (UL) Standard No.: UL Listed: UL508 (Listing), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA) Standard No.: cUL Listed: CSA C22.2 No.107.1, cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN55011 Group 1 Class BEmission AC mains: Conforms to EN55011 Group 1 Class B and based on FCC Class B
Applicable standard(VDE) Standard No.: VDE0160, VDE0805 Teil 1 File number:
Applicable standard(SEMI) F47-0706 (200 VAC input)
Applicable standard(Other) Conformed standard 2: Terminal block: Based on DIN EN50274 (VDE0660-514)
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 75 CEL(with no icing or condensation)
Ambient humidity Operating: 25 to 85%Storage: 25 to 90%(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type

Omron Power Supply S8TX Series S8TS-06024
Omron Power Supply S8TX Series S8TS-06024
Basic Block , Screw Terminal , Input 100 to 240 VAC , Output 24 V 2.5 APower rating 60 WEfficiency 80% TYP. ï¼ˆAt rated input, 100% load)Rated input voltage 100 t
Omron Power Supply S8VS Series S8VS-24024B-F
Omron Power Supply S8VS Series S8VS-24024B-F
Total Run Time Monitor , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt 200 
Omron Power Supply S8VS Series S8VS-06024B-F
Omron Power Supply S8VS Series S8VS-06024B-F
Standard Model , Input 100 to 240 VAC , 120 W , Output 24 V 5 APower rating 120 WEfficiency 84% TYP. ï¼ˆAt 100 VAC input)87% TYP. ï¼ˆAt 200 VAC input)Rate
Omron S8JX Switch Mode Power S8JX-G05012C
Omron S8JX Switch Mode Power S8JX-G05012C
Covered type , Input 100 to 240 VAC , 50 W , Output 12 V 4.2 A , Front-mounting typePower rating 50 WEfficiency 81% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron Power Supply S8EX Series S8EX-N03012L
Omron Power Supply S8EX Series S8EX-N03012L
With chassis , Input 100 to 240 VAC , 30W , Output 12V 2.5APower rating 30 WEfficiency 82% Min. ï¼ˆAt 100 VAC input)83% Min. ï¼ˆAt 200 VAC input)Rated i
Omron S8JX Switch Mode Power S8JX-G05048C
Omron S8JX Switch Mode Power S8JX-G05048C
Covered type , Input 100 to 240 VAC , 50 W , Output 48 V 1.1 A , Front-mounting typePower rating 50 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron S8JX Switch Mode Power S8JX-P05012D
Omron S8JX Switch Mode Power S8JX-P05012D
Open-Frame Type , Input 100 to 240 VAC , 50W , Output 12V 4.2A , DIN Rail mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VACAllowable-inp
Omron S8JX Switch Mode Power S8JX-G01512
Omron S8JX Switch Mode Power S8JX-G01512
Open-Frame Type , Input 100 to 240 VAC , 15W , Output 12V 1.3A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-input volta
Omron Power Supply S8EX Series S8EX-BP15048LC
Omron Power Supply S8EX Series S8EX-BP15048LC
With chassis and cover , Input 100 to 240 VAC , 150W , Output 48V 3.2APower rating 150 WEfficiency 85% Min. ï¼ˆAt 100 VAC input)88% Min. ï¼ˆAt 200 VAC in
Omron Power Supply S8JX Switch Mode Power S8JX-P30048N
Omron Power Supply S8JX Switch Mode Power S8JX-P30048N
Covered type , Input 100 to 240 VAC , 300W , Output 48V 7A , Without mounting brackets typePower rating 300 WEfficiency 78% Min.Rated input voltage 100 to 240 VACAllowabl