Omron Power Supply S8VM Series S8VM-05015

Omron Power Supply S8VM Series S8VM-05015
share

Standard Type , Open-Frame Type , Bottom Mounting Type , Input 100 to 240 VAC , 50 W , Output 15 V 3.5 A
Power rating 50 W
Efficiency 79% Min.
Rated input voltage 100 to 240 VAC
Allowable-input voltage variable range 85 to 264 VAC
Frequency 50/60 Hz (47 to 63 Hz Single-phase)
Rated input current 0.8 A Max. ï¼ˆAt 100 VAC input)0.4 A Max. ï¼ˆAt 200 VAC input)
Power factor 0.98 Min. (At 100 VAC input)0.94 Min. (At 200 VAC input)
Harmonic Current EN61000-3-2
Leakage current 0.4 mA Max. (At 100 VAC input)0.75 mA Max. (At 200 VAC input)
Inrush current 17.5 A Max. ï¼ˆAt 100 VAC input (For cold start at 25 CEL))35 A Max. ï¼ˆAt 200 VAC input (For cold start at 25 CEL))
Rated output voltage 15 VDC
Output voltage variable range -20 to +20% (With V. ADJ)(The output voltage may increase beyond the allowable voltage range (up to +20% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 1.2%(p-p) Max.
Static input variation influence 0.4% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence 0.8% Max. (At rated input, 0 to 100% load)
Ambient temperature variation influence 0.02 %/CEL Max. (At rated input/output voltage)
Rated output current 3.5 A
Start up time 800 ms Max. ï¼ˆAt rated input/output voltage)
Hold time 20 ms TYP.
Overload protection 105% to 160% of the rated output currentInverted L voltage drop, Automatic reset
Overvoltage protection Operated at 125 to 145 % of the rated output voltage, Shut-offResetting: Reset the power by turning it back (OFF time: at least 3 min)
Maintenance forecast monitor output No
Total run time monitor output No
Undervoltage alarm output No
Power failure alarm indication No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Applicable standard (UL) Standard No.: UL508 (Listing), UL60950-1, UL1604 (Listing, Class I / Division 2)
Applicable standard (CSA) Standard No.: cUL: CSA C22.2 No.14, No.213 (Class I / Division 2), cUR: CSA C22.2 No.60950-1
Applicable standard (EN) Standard No.: EN50178, EN60950-1
Applicable standard (EC Directive (EMI)) Emission Enclosure: Conforms to EN61204-3 Class BEmission AC mains: Conforms to EN61204-3 Class B and based on FCC Class B
Applicable standard(SEMI) F47-0200 (200 VAC input)
Applicable standard(Other) Conformed standard 2: VDE0106 / P100
Ambient temperature Operating: -10 to 70 CELStorage: -25 to 65 CEL(with no icing or condensation)
Ambient humidity Operating: 30 to 85% RHStorage: 25 to 90% RH(With no icing or condensation)
Dielectric strength Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)Between all inputs and PE/FG terminals: 2 kVAC for 1 min (Detection current: 20 mA)Between all outputs and PE/FG terminals: 500 VAC for 1 min (Detection current: 100 mA)
Insulation resistance Between all outputs and all inputs/ PE/FG terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Open-frame type
Mounting type Bottom-mounting type
Attachment Instruction manual
Weight 290 g Max.

Omron S8JX Switch Mode Power S8JX-G05024C
Omron S8JX Switch Mode Power S8JX-G05024C
Covered type , Input 100 to 240 VAC , 50 W , Output 24 V 2.1 A , Front-mounting typePower rating 50 WEfficiency 83% Min.Rated input voltage 100 to 240 VACAllowable-i
Omron S8JX Switch Mode Power S8JX-G05005CD
Omron S8JX Switch Mode Power S8JX-G05005CD
Covered type , Input 100 to 240 VAC , 50 W , Output 5 V 10 A , DIN Rail mounting typePower rating 50 WEfficiency 76% Min.Rated input voltage 100 to 240 VAC
Omron Power Supply S8VS Series S8VS-09024BP
Omron Power Supply S8VS Series S8VS-09024BP
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 90 W , Output 24 V 3.75 APower rating 90 WEfficiency 83% TYP. ï¼ˆAt 100 VAC input)85% TYP. ï¼ˆAt&nbs
Omron Power Supply S8VS Series S8VS-12024BE
Omron Power Supply S8VS Series S8VS-12024BE
Standard Model , Input 100 to 240 VAC , 30 W , Output 12 V 2.5 APower rating 30 WEfficiency 81% TYP. ï¼ˆAt 100 VAC input)80% TYP. ï¼ˆAt 200 VAC input)Rate
Omron S8JX Switch Mode Power S8JX-G01505C
Omron S8JX Switch Mode Power S8JX-G01505C
Covered type , Input 100 to 240 VAC , 15 W , Output 5 V 3 A , Front-mounting typePower rating 15 WEfficiency 68% Min.Rated input voltage 100 to 240 VACAllowable-inpu
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Omron Power Supply S8JX Switch Mode Power S8JX-P15048C
Covered type , Input 100 to 240 VAC , 150W , Output 48V 3.3A , Front-mounting typePower rating 150 WEfficiency 82% Min.Rated input voltage 100 to 240 VACAllowable-input voltag
Omron Power Supply S8EX Series S8EX-N01505
Omron Power Supply S8EX Series S8EX-N01505
Open type , Input 100 to 240 VAC , 15W , Output 5V 3APower rating 15 WEfficiency 74% Min. ï¼ˆAt 100 VAC input)74% Min. ï¼ˆAt 200 VAC input)Rated input&n
Omron Power Supply S8VS Series S8VS-24024A-F
Omron Power Supply S8VS Series S8VS-24024A-F
Maintenance Forecast Monitor Type , Input 100 to 240 VAC , 240 W , Output 24 V 10 APower rating 240 WEfficiency 85% TYP. ï¼ˆAt 100 VAC input)88% TYP. ï¼ˆAt&nbs
Omron S8JX Switch Mode Power S8JX-G15024
Omron S8JX Switch Mode Power S8JX-G15024
Open-Frame Type , Input 100 to 240 VAC, 150W , Output 24V 6.5A , Front-mounting typePower rating 150 WEfficiency 86% Min.Rated input voltage 100 to 240 VACAllowable-input voltage&n
Omron S8JX Switch Mode Power S8JX-G15024D
Omron S8JX Switch Mode Power S8JX-G15024D
Open-Frame Type , Input 100 to 240 VAC , 150W , Output 24V 6.5A , DIN Rail mounting typePower rating 150 WEfficiency 86% Min.Rated input voltage 100 to 240 VACAllowable-i