Categories
- power supply
- TDK Lambda Power Supply
- Yamaha Power Supply
- Omron Power Supply
- Plus Power Supply
- Bestec Power Supply
- Sorensen Power Supply
- Antec Power Supply
- Meanwell Power Supply
- Weidmuller Power Supply
- Hipro Power Supply
- Sparkle Power Supply
- Lenovo Power Supply
- Zippy Power Supply
- Enermax Power Supply
- Agilent Power Supply
- Phihong Power Supply
- Liteon power supply
- Acble Power Supply
- Instek Power Supply
- Zalman Power Supply
- FSP Power Supply
- Aopen Power Supply
- Spellman Supply
- Delta Supply
- Cosel Supply
- Aj`s Power Source Supply
- Coolmax Supply
- MEAN WELL Power Supply
- SENDON Power Supply
- MGE Power Supply
- UPS Power Supply
- APC UPS Power Supply
- Riello UPS Power Supply
- EATON UPS Power Supply
- SANTAK UPS Power Supply
- Siemens UPS Power Supply
- Powerware UPS Power Supply
- OMRON UPS Power Supply
- Mitsubishi UPS Power Suppply
- DELTA Uninterruptible Power Supply
- EAST UPS Power Supply
- EMERSON UPS Power Supply
- Fuji UPS Power Supply
- EFFEKTA Uninterruptible Power Supply
- Gutor UPS Power Supply
- KELONG UPS Power Supply
- LADIS Uninterruptible Power Supply
- CBC UPS Power Supply
- Phoenix UPS Power Supply
- SVC Uninterruptible Power Supply
- Avaya UPS Power Supply
- NETCCA Uninterruptible Power Supply
- battery
- inverter
- Xantrex inverter
- Samlex inverter
- Schumacher inverter
- KACO inverter
- Wagan inverter
- AIMS inverter
- Victron inverter
- Targus inverter
- Whistler inverter
- Enphase inverter
- Satcon inverter
- Sima inverter
- Kensington inverter
- Exeltech inverter
- Stanley inverter
- ABB inverter
- SMA inverter
- Hyundai inverter
- Mastervolt inverter
- YAMAHA inverter
- Belkin inverter
- Microtek inverter
- Growatt inverter
- TDK inverter
- TOSHIBA inverter
- Su kam inverter
- Omnik inverter
- Ingeteam inverter
- Samil Power inverter
- Sungrow inverter
- Cobra inverter
- Power Bright inverter
- Bestek inverter
Contact Us
- A&S Power Supply Co.,Ltd
- Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
- Tel:+86-28-65376776
- Fax:+86-28-86129221
- Email:inverter@electrical8.com
- Contact Person:Karina
Powerware 9305 UPS PW9305-50I-N

share
Specifications:
Rating 50 kVA
Capacity (VA/Watts) 50 kVA/35 kW
Dimensions WxDxH (mm) 520x788x1530
Weight (kg) 260
Input connection Hardwired
Output connection Hardwired
Typical runtime (Full load) 7 min
(Half load) 20 min
Powerware 9170 Online UPS PW12S9K
Specifications:Power Rating (VA) 9000Rated Load Capacity (Watts) 7500Standard Warranty 2 years parts; 90 days onsite laborOptional Warranties Cover parts and labor up to 5 years Electrical InputInput Voltage 208-240 neutral requiredInput Connection Hardwired hardwired terminal Electrical OutputOut
Specifications:Power Rating (VA) 9000Rated Load Capacity (Watts) 7500Standard Warranty 2 years parts; 90 days onsite laborOptional Warranties Cover parts and labor up to 5 years Electrical InputInput Voltage 208-240 neutral requiredInput Connection Hardwired hardwired terminal Electrical OutputOut
Powerware BPIII 300 Industrial UPS 225-300 kVA
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than
Specifications:Input SpecificationsFrequency range: (60 Hz) 57-63 HzSurge protection: Meets ANSI C62.41Category A & B: EN 50091-2, and EN 50082-2Power factor: 0.95 typical at full load with input filterInput currentdistortion: less than 7% with input filterOutput SpecificationsVoltage THD: Less than
Powerware BPIII HE UPS 62.5 kVA/50 kw
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Specifications:Configuration: 3-Phase, 3 wire plus groundRange Nominal +10%, –15%Frequency range Nominal ±3 Hz (60 Hz)Power factor Minimum 0.9 with filterPower walk-in 3-60 seconds to full loadInput current 10% THD under nominal conditions distortion with filterTransient protection 6kV OC, 3 kV S
Powerware 9120 UPS PW9120 3000i
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
Descriptions:The Powerware 9120 UPS is designed for those applicationsthat need maximum protection in the 700 VA – 3 kVA range.With its high-frequency, doubleconversion online topology, providingnonstop clean sine wave power, advanced communicationsand space-saving tower design, the Powerware 9120
Powerware 9330 UPS Model 30 30kVA/21kW
Descriptions: the Powerware 9330 offers the highest reliability for critical systems in this power range.And provides IT managers with a state-of-the-art UPS designed for optimal efficiency and the highest reliability. Powerware 9330 delivers the highest performance by using digital signal
Descriptions: the Powerware 9330 offers the highest reliability for critical systems in this power range.And provides IT managers with a state-of-the-art UPS designed for optimal efficiency and the highest reliability. Powerware 9330 delivers the highest performance by using digital signal
Powerware 9125 Rackmount UPS 91253000eRM
Specifications:Rating 3000VACapacity (VA/Watts) 3000/2100 Dimensions WxDxH (mm) 432X607X89 Weight (kg) 37Input Connection IEC320/16AOutput Connection 4xIEC320 10A 1xIEC320 16AOperationalNominal input voltage (Vac) 220/230/240 VacInput voltage range 160-288 VAC
Specifications:Rating 3000VACapacity (VA/Watts) 3000/2100 Dimensions WxDxH (mm) 432X607X89 Weight (kg) 37Input Connection IEC320/16AOutput Connection 4xIEC320 10A 1xIEC320 16AOperationalNominal input voltage (Vac) 220/230/240 VacInput voltage range 160-288 VAC
Powerware 5119 Rackmount UPS PW5119 2000iRM
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Specifications:Electrical InputVoltage 120 and 230 VAC NominalOn Line Voltage Range -30%, +20% for nominal voltages; user selectable extended range of -35%, +20% (-30%, +15% for 127 and 240 VAC)Nominal Input Frequency 50/60 Hz; auto-selection (60 Hz only for 120 and 127 VAC)Frequency Tolerance No
Powerware BPII HE UPS 10 kVA/8 kw
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Descriptions:Balanced Power II HE and Balanced Power II-S HE (BPII HE and BPII-S HE) offer the reliability of true online technology utilizing digital signal processing (DSP) control and monitoring. In addition, the BPII HE and BPII-S HE use the patented technology of an inverter software harmonic c
Powerware 3110 UPS PW3110 700
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Descriptions:Ideal for PC-based applications, the Powerware 3110 provides affordable protection in a sleek, well-designed unit that can fit undera desk or can be wall-mounted.
Powerware 5119 UPS PW5119 2000i
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc
Technical Specifications:ELECTRICAL INPUTVoltage 120 and 230 VAC nominal;Online Voltage -30%, +20% for nominal voltages; user-selectableRange extended range of -35%, +20% (-30%, +15% for 127and 240 VAC)Nominal Input 50/60 Hz; auto-selection (60 Hz only for 120 and 127 Vac)FrequencyFrequency Toleranc