Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / UPS Power Supply / Riello UPS Power Supply / Riello Dialog Vision UPS DVR 1100

Riello Dialog Vision UPS DVR 1100

Riello Dialog Vision UPS DVR 1100
share

Specifications:
INPUT
Rated power 1100 VA
Voltage 230 Vac
Frequency 50/60 Hz with autorange
Frequency tolerance ± 10Hz
OUTPUT and INVERTER OUTPUT
Rated power 1100 VA
Active power 740 W
Number phases 1
Waveform Sinewave
Frequency 50 or 60 Hz with autorange
BATTERIES
Type Maintenance-free sealed lead acid
Typical recharge time 2÷4 h

Riello Vision UPS VST 1100
Riello Vision UPS VST 1100
Specifications:INPUTRated power 1100 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 1100 VAActive power 880 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorangeBATTERIESType Maintenance-free sealed lead acidTypical recha
Riello Master HP UPS MHT 300
Riello Master HP UPS MHT 300
SpecificationsINPUTRated power 300000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 423 ACurrent distorsion
Riello Master Industrial UPS MIM 80
Riello Master Industrial UPS MIM 80
Specifications: INPUT Rated power 80000 VA Voltage 400 Vac three-phase Vac Voltage tolerance ± 20% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0.93 Current distorsion <5% Soft start 0-100% in 10" BY PASS Rated voltage 400 Vac three-phase selectable 380
Riello Vision Dual UPS VSD 2200 ER
Riello Vision Dual UPS VSD 2200 ER
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1760 W Number phases 1 Crest factor (Ipea
Riello Multi Sentry UPS MST 120
Riello Multi Sentry UPS MST 120
Specifications:INPUTRated power 120000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Multi Sentry UPS MCT 15
Riello Multi Sentry UPS MCT 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Dual (Low Power) UPS SDH 2200
Riello Sentinel Dual (Low Power) UPS SDH 2200
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 200 - 253Frequency
Riello Sentinel Power UPS SPT 8000
Riello Sentinel Power UPS SPT 8000
Specifications:INPUTRated power 8000 VAVoltage 220-230-240 Vac single-phase or 380-400-415 Vac three-phase with neutral VacVoltage tolerance 170 Vac @ load 100% / 140 Vac @ load 50%Frequency 50/60 Hz ± 5 HzBY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequ
Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Specifications:INPUTRated power 10000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERT
Riello Multi Sentry UPS MST 40
Riello Multi Sentry UPS MST 40
Specifications:INPUTRated power 40000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25