Specifications:
INPUT
Voltage 380 - 400 - 415 Vac three-phase Vac
Frequency 45 - 65 Hz
Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)
Soft start 0 - 100% in 120’’ (selectable)
Voltage Range 400 V + 20% /- 25%
BY PASS
Rated voltage 380 - 400 - 415 Vac three-phase + N
Rated frequency 50 or 60 Hz (selectable)
OUTPUT and INVERTER OUTPUT
Rated power 80000 VA
Active power 72000 W
Output Voltage 380 - 400 - 415 Vac three-phase + N (selectable)
Crest factor (Ipeak/Irms) 3:1
Static stability ± 1%
Dynamic stability ± 5% in 10 ms
Frequency 50 or 60 Hz (selectable)
Voltage distortion with distorcing load < 3% with non-linear load
Voltage distortion with linear load < 1% with linear load
Frequency stability 0.05%

Riello Multi Sentry UPS MST 15
Riello Multi Sentry UPS MST 15
Specifications:INPUTRated power 15000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Sentinel Pro UPS SEP 2200 ER
Riello Sentinel Pro UPS SEP 2200 ER
Specifications:INPUTRated power 2200 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master MPS UPS MPM 100
Riello Master MPS UPS MPM 100
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen
Riello Multi Sentry UPS MSM 10
Riello Multi Sentry UPS MSM 10
Specifications:INPUTRated power 10000 VAVoltage 230 Vac single-phase or 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 230Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5%
Riello Sentinel Power Green UPS SPH 20 ER
Riello Sentinel Power Green UPS SPH 20 ER
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 20000 VAActive power 18000 WWaveform Sinusoidal
Riello Sentinel Power Green UPS SPH 8
Riello Sentinel Power Green UPS SPH 8
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 8000 VAActive power 7200 WWaveform SinusoidalOVERLOAD TIMES
Riello Multi Sentry UPS MST 20
Riello Multi Sentry UPS MST 20
Specifications:INPUTRated power 20000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Vision UPS VST 800
Riello Vision UPS VST 800
Specifications:INPUTRated power 800 VAVoltage 230 VacFrequency 50/60 Hz with autorangeFrequency tolerance ± 5%OUTPUT and INVERTER OUTPUTRated power 800 VAActive power 540 WNumber phases 1Waveform SinewaveFrequency 50/60 Hz with autorange
Riello Sentinel Pro UPS SEP 3000 ER
Riello Sentinel Pro UPS SEP 3000 ER
Specifications:INPUTRated power 3000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Master HE UPS MHE 500
Riello Master HE UPS MHE 500
Specifications: INPUT Rated power 500000 VA Voltage 400 Vac three-phase Vac Voltage tolerance + 20% - 25% Frequency 50/60 Hz with autorange Frequency tolerance 45/65 Hz Power factor 0,99 Input current 702 A Current distorsion <3% Soft start 0-100% in 10 BY PASS Rated voltage 400 Vac t