Specifications:
INPUT
Rated power 600 VA
Voltage 220-240 Vac
Voltage tolerance 230 Vac (+ 20 / - 25%)
Frequency 50/60 Hz auto sensing
OUTPUT and INVERTER OUTPUT
Rated power 600 VA
Active power 360 W
Number phases 1
Wave form on battery Pseudo sinewave
Frequency on battery operation 50 or 60 Hz (± 1%)
BATTERIES
Type Maintenance-free sealed lead-acid
Typical recharge time 2÷4 h
ENVIRONMENTAL
Altitude max 6000 m max. elevation
Communication USB and RS232
Safety compliance EN 62040-1 and Directives 73/23 EEC, 93/68 EEC
EMC conformance EN 62040-2 cl. B and Directives 89/336 EEC, 92/31 EEC, 93/68 EEC
Accessories provided user guide
Protection rating 1
Marks CE
Operating temperature 0 ÷ 40 °C
Relative humidity 0-95% no condensing

Riello Master MPS UPS MPM 10
Riello Master MPS UPS MPM 10
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 360-400-420 Vac three-phase + NRated frequen
Riello iDialog UPS IDG 800
Riello iDialog UPS IDG 800
Specifications:INPUTRated power 800 VAVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 25%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 800 VAActive power 480 WNumber phases 1Wave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 1%)
Riello Master MPS UPS MPT 15
Riello Master MPS UPS MPT 15
Specifications:INPUTVoltage 380 - 400 - 415 Vac three-phase VacFrequency 45 - 65 HzFrequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel)Soft start 0 - 100% in 120’’ (selectable)Voltage Range 400 V + 20% /- 25%BY PASSRated voltage 380 - 400 - 415 Vac three-phase + NRated fre
Riello Multi Sentry UPS MCT 12
Riello Multi Sentry UPS MCT 12
Specifications:INPUTRated power 12000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.25
Riello Master MPS UPS MPT 160
Riello Master MPS UPS MPT 160
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master HP UPS MHT 300
Riello Master HP UPS MHT 300
SpecificationsINPUTRated power 300000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 423 ACurrent distorsion
Riello Master HP UPS MHT 400
Riello Master HP UPS MHT 400
SpecificationsINPUTRated power 400000 VAVoltage 400 Vac three-phase VacVoltage tolerance + 20% - 25%Frequency 50/60 Hz with autorangeFrequency tolerance 45/65 HzPower factor 0,99Input current 564 ACurrent distorsion
Riello Sentinel Power Green UPS SPH 10
Riello Sentinel Power Green UPS SPH 10
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 10000 VAActive power 9000 WWaveform SinusoidalOVERLOAD TIME
Riello Sentinel Dual (Low Power) UPS SDH 1000
Riello Sentinel Dual (Low Power) UPS SDH 1000
Specifications:INPUTRated power 1000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Net Power UPS NPW 600
Riello Net Power UPS NPW 600
Specifications:INPUTVoltage 220-240 VacVoltage tolerance 230 Vac (+ 20 / - 26%)Frequency 50/60 Hz auto sensingOUTPUT and INVERTER OUTPUTRated power 600 VAActive power 360 WWave form on battery Pseudo sinewaveFrequency on battery operation 50 or 60 Hz (± 0.5%)BATTERIESType Maintenance-free sealed le