Specifications:
INPUT
Rated power 800 VA
Voltage 230 Vac
Frequency 50/60 Hz with autorange
Frequency tolerance ± 10Hz
OUTPUT and INVERTER OUTPUT
Rated power 800 VA
Active power 540 W
Number phases 1
Waveform Sinewave
Frequency 50 or 60 Hz with autorange
BATTERIES
Type Maintenance-free sealed lead acid
Typical recharge time 2÷4 h

Riello Multi Sentry UPS MST 100
Riello Multi Sentry UPS MST 100
Specifications:INPUTRated power 100000 VAVoltage 400 Vac three-phase + N VacVoltage tolerance ± 20%Frequency tolerance 40/72 HzPower factor 0.99BY PASSRated voltage 400Voltage tolerance ± 15% (selectable from ± 5% to ± 25%)Rated frequency 50/60 HzFrequency tolerance ± 5% (selectable from ± 0.2
Riello Sentinel Pro UPS SEP 1000 ER
Riello Sentinel Pro UPS SEP 1000 ER
Specifications:INPUTRated power 1000 VAVoltage 220-230-240 VacVoltage tolerance 140 Vac < Vin < 276 Vac @50% LOAD / 184 Vac < Vin < 276 Vac @ 100% LOADFrequency 50/60 HzFrequency tolerance 50 Hz ± 5% / 60 Hz ± 5%Power factor > 0.99Current distorsion ≤7%BY PASSVoltage tolerance 180 - 264Frequency
Riello Sentinel Power Green UPS SPH 8
Riello Sentinel Power Green UPS SPH 8
Specifications:INPUTVoltage 220-230-240 VacFrequency 50/60 Hz +/- 10 HzBY PASSVoltage tolerance 160 - 276 Vac (selectable in Economy Mode or Smart Active Mode)Frequency tolerance Selected frequency ±10%OUTPUT and INVERTER OUTPUTRated power 8000 VAActive power 7200 WWaveform SinusoidalOVERLOAD TIMES
Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Riello Sentinel Dual (High Power) UPS SDL 10000 TM
Specifications:INPUTRated power 10000 VAVoltage 380-400-415 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤5%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERT
Riello Vision Dual UPS VSD 2200 ER
Riello Vision Dual UPS VSD 2200 ER
Specifications: INPUT Rated power 2200 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 2200 VA Active power 1760 W Number phases 1 Crest factor (Ipea
Riello Vision Dual UPS VSD 1500
Riello Vision Dual UPS VSD 1500
Specifications: INPUT Rated power 1500 VA Voltage 220-230-240 Vac Frequency 50/60 Hz with automatic selection Frequency tolerance ± 5Hz Power factor > 0,98 Current distorsion < 7% OUTPUT and INVERTER OUTPUT Rated power 1500 VA Active power 1350 W Number phases 1 Crest factor (Ipea
Riello Sentinel Dual (High Power) UPS SDL 3300
Riello Sentinel Dual (High Power) UPS SDL 3300
Specifications:INPUTRated power 3300 VAVoltage 220-230-240 VacFrequency 50/60 Hz ± 5 HzPower factor >0.98Current distorsion ≤7%BY PASSVoltage tolerance 180÷264 Vac (selectable in Economy Mode and SMART ACTIVE Mode)Frequency tolerance Selected frequency ± 5% (user configurable)OUTPUT and INVERTE
Riello Master MPS UPS MPT 60
Riello Master MPS UPS MPT 60
Specifications: INPUT Voltage 380 - 400 - 415 Vac three-phase Vac Frequency 45 - 65 Hz Frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Soft start 0 - 100% in 120’’ (selectable) Voltage Range 400 V + 20% /- 25% BY PASS Rated voltage 380 - 400 - 415 Vac three-ph
Riello Master FC400 UPS MFC 80
Riello Master FC400 UPS MFC 80
Specifications: SKU MFC80 Power 80kVA/64kW Runtime Add external battery extension Input Connection Hardwired terminals Input Voltage 380/400/415Vac 3phase, 45-65Hz Output Connection Hardwired terminals Output Voltage 208Vac 3phase+N +/-1%, 400Hz +/- 0.05% Dimensions (WxDxH) 550x740x1200mm N
Riello Master HP UL UPS MHT UL 80
Riello Master HP UL UPS MHT UL 80
Specifications: Input voltage and frequency 480 VAC Three phase - 45~65 Hz ±2% selectable from ±1% to ±5% from front panel Output voltage ans frequency 380, 400, 415 VAC Three phase - 50/60 Hz (selactable Waveform Sinusoidal Power(KVA/KW)80/72 %Input voltage distoration (THDi) <3 Output