With peak efficiencies of 98.3%, the transformerless Sunny Boy TL-US provide their owners with high yields. The power classes, finely tiered from 6 kW to 11kW, are ideal for designing mid-size solar power plants with precision. Its reduces weight, together with its security features, make our Sunny Boy the ideal inverter.
Innovative
First transformerless SMA inverter to be certified in accordance with UL 1741 with safety standards from IEC 62109
First inverter with arc-fault circuit interrupter listed according to UL1699B
Economical
Maximum efficiency of 98.3%
The best MPP tracking efficiency with OptiTrac MPP tracking
Transformerless, with H5 topology
OptiCool active temperature management
Reliable
Integrated DC switch-disconnector
SMA Power Balancer for threephase grid connection
With arc-fault circuit interrupter (AFCI)
Input (DC)
Max. recommended PV power (@ module STC) 13750 W
Max. DC power (@ cos Ï† = 1) 11500 W
Max. input voltage 600 V
MPP voltage range / rated input voltage 345 V â€“ 480 V / 379 V
Min. input voltage / initial input voltage 345 V / 360 V
Max. input current 33.3 A
Max. input current per string 33.3 A
Number of independent MPP inputs 1
Strings per MPP input @ Combiner Box 6
-Output (AC)
Rated power / max. apparent AC power 11000 W / 11000 VA
Nominal AC voltage / nominal AC voltage range 240 V / 211 V â€“ 264 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Max. output current 45.8 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 2
-Efficiency
CEC efficiency / max. efficiency 98 % / 98.3 %
-Protective devices
DC reverse polarity protection yes
AC short-circuit current capability yes
Galvanic isolation —
All-pole-sensitive residual-current monitoring unit yes
Arc-fault circuit interrupter (according to UL 1699B) yes
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) IV
-General data
Dimensions (W / H / D) 470 / 615 / 240 mm(18.4 / 24.1 / 9.5 inch)
Dimensions of DC Disconnect (W / H / D) 187 / 297 / 190 mm(7.28 / 11.7 / 7.5 inch)
Weight 35 kg / 78 lb
Weight of DC Disconnect 3.5 kg / 8 lb
Operating temperature range -40 °C ... +60 °C /-40 °F ... +140 °F
Noise emission (typical) 46 dB(A)
Self-consumption (night) 0.15 W
Topology Transformerless H5
Cooling concept OptiCool
Degree of protection NEMA 3R
Degree of protection of connection area NEMA 3R
Max. permissible value for relative humidity (non-condensing) 100 %
-Features
DC connection Screw terminal
AC connection Screw terminal
Display Text line
Interface: RS485 /Bluetooth opt. / opt.
Warranty: 10 / 15 / 20 years yes / opt. / opt.
Certificates and approvals (more available on request) UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, UL 1699B

SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SAM Solar Inverters without Transformer SUNNY BOY 1600TL
SAM Solar Inverters without Transformer SUNNY BOY 1600TL
Combining a broad input voltage range and a broad input current range, the transformerless Sunny Boy can be connected to nearly all standard crystalline PV modules. As&nb
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 11000TL
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 11000TL
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SMA Solar Inverters with Transformer SUNNY BOY 3000-US
SMA Solar Inverters with Transformer SUNNY BOY 3000-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SAM Solar Inverters without Transformer SUNNY BOY 3000TL-21 SINGLE TRACKER
SAM Solar Inverters without Transformer SUNNY BOY 3000TL-21 SINGLE TRACKER
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in
SMA Solar Inverters with Transformer SUNNY BOY 700-US
SMA Solar Inverters with Transformer SUNNY BOY 700-US
Implementing modular PV plants with ease is not a problem with the UL-certified Sunny Boy 700-US. It is optimally suited for expanding new or already existing PV pla
SMA Solar Inverters with Transformer SUNNY BOY 2000HF-US
SMA Solar Inverters with Transformer SUNNY BOY 2000HF-US
This is the new generation of inverters designed for the countries with UL listing â€“ packed full of the latest SMA technology, these devices provide the highest&nb
SAM Solar Inverters without Transformer SUNNY BOY 2500TL-21 SINGLE TRACKER
SAM Solar Inverters without Transformer SUNNY BOY 2500TL-21 SINGLE TRACKER
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in