Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant designs which specify for the displacement factor cos Ï† and the corresponding percentage of reactive power. Large PV power stations can now make optimum use of grid distribution capacities, which significantly contributes to the success of renewable energy.
Flexible
Reactive power supply
High yields
Maximum efficiency of 97.7 %
Transformerless, with H5 topology
OptiCool active temperature management
Reliable
Pluggable SMA Power Balancer for three-phase grid connection
Integrated ESS DC switchdisconnector
Monitored string fuses
Simple
SUNCLIX DC plug-in system
-Input (DC)
Max. DC power (@ cos Ï† = 1) 10350 W
Max. input voltage 700 V
MPP voltage range / rated input voltage 333 V â€“ 500 V / 350 V
Min. input voltage / initial input voltage 333 V / 400 V
Max. input current 31 A
Max. input current per string 31 A
Number of independent MPP inputs / strings per MPP input 1 / 5


Output (AC)
Rated power (@ 230 V, 50 Hz) 10000 W
Max. apparent AC power 10000 VA
Nominal AC voltage / range 220 V, 230 V, 240 V / 180 V â€“ 265 V
AC power frequency / range 50 Hz, 60 Hz / -6 Hz ... +5 Hz
Rated power frequency / rated grid voltage 50 Hz / 230 V
Max. output current 44 A
Power factor at rated power 1
Adjustable displacement power factor 0.8 overexcited ... 0.8 underexcited
Feed-in phases / connection phases 1 / 1
Power balancing yes

-Efficiency
Max. efficiency / European weighted efficiency 97.7 % / 97.2 %
Protective devices
Reverse current protection / DC disconnect device Optional (fuses) / yes
Ground fault monitoring / grid monitoring yes / yes
DC reverse polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / â€”
All-pole-sensitive residual-current monitoring unit yes
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III

General data
Dimensions (W / H / D) 468 / 613 / 242 mm(18.4 / 24.1 / 9.5 inch)
Weight 35 kg / 77.16 lb
Operating temperature range -25 °C ... +60 °C /-13 °F ... +140 °F
Noise emission (typical) 45 dB(A)
Self-consumption (night) 0.25 W
Topology Transformerless
Cooling concept OptiCool
Degree of protection (according to IEC 60529) IP65
Degree of protection of connection area (according to IEC 60529) IP65
Climatic category (according to IEC 60721-3-4) 4K4H
Max. permissible value for relative humidity (non-condensing) 100 %

-Features
DC coupling SUNCLIX
AC coupling Screw terminal
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt.
Certificates and approvals (more available on request) CE, VDE0126-1-1, AR4105, EN50438¹, C10/11, PPDS, IEC61727, UTEC15-712-1, RD1699, RD 661/2007

SMA Solar Inverters with Transformer SUNNY BOY 2500HF
SMA Solar Inverters with Transformer SUNNY BOY 2500HF
The Sunny Boy HF offers a nearly unlimited range of options for the planning phase. A wide input voltage range of 175-700 volts means that most configurations can&nb
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TL
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 10000TL
At home with leading-edge technology and top yields: The Sunny Tripower PV plant with 5 to 9 kW of power is setting new standards for home systems. It features&
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SAM Solar Inverters without Transformer SMA PV OFFSET BOX
SAM Solar Inverters without Transformer SMA PV OFFSET BOX
Certain kinds of PV modules are subject to power degradation when exposed to negative voltage to ground (polarization). The PV Offset Box maintains the performance capability&
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
SMA Solar Inverters with Transformer SUNNY BOY 4000-US
Specially designed for countries that require UL listing, these Sunny Boy inverters guarantee a safe installation process thanks to the automatic grid voltage detection¹. The 
SAM Solar Inverters without Transformer SUNNY TRIPOWER 15000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 15000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY BOY 2500HF-US
SMA Solar Inverters with Transformer SUNNY BOY 2500HF-US
This is the new generation of inverters designed for the countries with UL listing â€“ packed full of the latest SMA technology, these devices provide the highest&nb
SMA Solar Inverters with Transformer SUNNY BOY 3300
SMA Solar Inverters with Transformer SUNNY BOY 3300
It is robust, easy-to-handle, and, thanks to its galvanic isolation, can be used in all kinds of AC grids: the Sunny Boy 3300 / 3800. Due to its suitability&nbs
SMA Solar Inverters with Transformer SUNNY BOY 700-US
SMA Solar Inverters with Transformer SUNNY BOY 700-US
Implementing modular PV plants with ease is not a problem with the UL-certified Sunny Boy 700-US. It is optimally suited for expanding new or already existing PV pla