Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide flexibility in plant planning. The automatic grid voltage detection¹ allows easy and safe installation. Furthermore, the galvanic isolation provides flexible connection possibilities. The Sunny Boy inverters can be used with crystalline cells as well as thin-film PV modules.
UL listed
For countries that require UL listing (UL 1741 / IEEE 1547 / CAN CSA C22.2 107)
Economical
97 % peak efficiency
OptiCool active temperature management
Reliable
Galvanic isolation
Arc-fault circuit interrupter, optional (AFCI)
Simple
Automatic grid voltage detection¹
Integrated DC switch-disconnector
¹ US patent US7352549B1
208 V240 V277 V 208 V240 V277 V
-Input (DC)
Max. recommended PV power (@ module STC) 7500 W
Max. DC power (@ cos Ï† = 1) 6350 W
Max. input voltage 600 V
MPP voltage range / rated input voltage 250 V â€“ 480 V / 310 V
Min. input voltage / initial input voltage 250 V / 300 V
Max. input current 25 A
Max. string fuse on the DC disconnector 20 A
Number of independent MPP inputs 1
Strings per MPP input (@ DC disconnector) 4
-Output (AC)
Rated power / max. apparent AC power 6000 W / 6000 VA
Nominal AC voltage / nominal AC voltage range 208 V / 183 V â€“ 229 V240 V / 211 V â€“ 264 V277 V / 244 V â€“ 305 V
AC power frequency / range 60 Hz / 59.3 Hz ... 60.5 Hz
Max. output current 29 A25 A22 A
Power factor at rated power 1
Feed-in phases / connection phases 1 / 21 / 21 / 1
-Efficiency
CEC efficiency / max. efficiency 95.5 % / 96.9 %95.5 % / 96.8 %96 % / 97 %
-Protective devices
DC reverse polarity protection yes
AC short-circuit current capability yes
Galvanically isolated yes
Arc-fault circuit interrupter (in accordance with UL1699B)² opt.
Protection class (according to IEC 62103) I
Overvoltage category (according to IEC 60664-1) III
-General data
Dimensions (W / H / D) 470 / 615 / 240 mm(18.4 / 24.1 / 9.5 inch)
Dimensions of DC Disconnect (W / H / D) 187 / 297 / 190 mm(7.3 / 11.7 / 7.5 inch)
Weight 64 kg / 143 lb
Weight of DC Disconnect 3.5 kg / 8 lb
Operating temperature range² -25 °C ... +45 °C /-13 °F ... +113 °F
Noise emission (typical) 45 dB(A)
Self-consumption (night) 0.1 W
Topology LF transformer
Cooling concept OptiCool
Degree of protection NEMA 3R
Degree of protection of connection area NEMA 3R
Max. permissible value for relative humidity (non-condensing) 100 %
-Features
DC connection Screw terminal
AC connection Screw terminal
Display Text line
Interface: RS485 / Bluetooth opt. / opt.
Warranty: 10 / 15 / 20 years yes / opt. / opt.
Certifi cates and approvals (more available on request) UL1741, UL1998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1, C22.2, UL 1699B

SMA Solar Inverters with Transformer SUNNY BOY 1700
SMA Solar Inverters with Transformer SUNNY BOY 1700
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP
SAM Solar Inverters without Transformer SUNNY MINI CENTRAL 9000TLRP
Sunny Mini Central inverters with Reactive Power Control are the ideal solution when utility companies demand reactive power supply. They can be used to realize plant des
SMA Solar Inverters with Transformer SUNNY MINI CENTRAL 4600A
SMA Solar Inverters with Transformer SUNNY MINI CENTRAL 4600A
The Sunny Mini Central 4600A, 5000A and 6000A are installed wherever galvanic isolation is required. This means they can be universally used for many different types of&n
SAM Solar Inverters without Transformer SUNNY TRIPOWER 20000TL-10 Economic Excellence
SAM Solar Inverters without Transformer SUNNY TRIPOWER 20000TL-10 Economic Excellence
Peak performance and technological perfection at a significantly reduced specific price: the new Sunny Tripower TL Economic Excellence is the next logical step in the developm
SMA Solar Inverters with Transformer SUNNY BOY 3000
SMA Solar Inverters with Transformer SUNNY BOY 3000
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
SMA Solar Inverters with Transformer SUNNY BOY 6000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
SMA Solar Inverters with Transformer SUNNY BOY 7000-US
Maximum energy yields for a continuously expanding photovoltaic market: the Sunny Boys with UL listing is impressive with its excellent efficiency. Graduated power classes provide&
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
SAM Solar Inverters without Transformer SUNNY TRIPOWER 17000TL
Optiflex is the first of our new features.Its outstanding flexibility opens up endless possibilities.How? Through an asymmetrically dimensioned multistring input combined with a broad&n
SMA Solar Inverters with Transformer SUNNY BOY 1200
SMA Solar Inverters with Transformer SUNNY BOY 1200
Universally applicable: the Sunny Boy inverters 1200, 1700, 2500 and 3000 are used in the most diverse AC grids thanks to their galvanic isolation. In addition, the 
SAM Solar Inverters without Transformer SUNNY BOY 3000TL RPC
SAM Solar Inverters without Transformer SUNNY BOY 3000TL RPC
Electrifying detail: Thanks to the higher, 750 volt maximum DC input voltage, often times one less module string is needed because more modules can be switched on in