Cart()
 
 
Categories
Contact Us
  • A&S Power Supply Co.,Ltd
  • Address:469, Xinsheng Road, Gaoxin District, Chengdu, Sichuan, China
  • Tel:+86-28-65376776
  • Fax:+86-28-86129221
  • Email:inverter@electrical8.com
  • Contact Person:Karina
Home / Products / power supply / Sorensen Power Supply / DC / Sorensen Power Supply Sorensen XG 1700 Watt

Sorensen Power Supply Sorensen XG 1700 Watt

Sorensen Power Supply Sorensen XG 1700 Watt
share



Product Overview
The XG 1700 is an industry leading programmable DC power supply designed for test, production, laboratory, OEM and quality assurance applications. The XG 1700 is a 1700 Watt, 1U programmable power supply with constant voltage and constant current modes, automatic cross-over and numerous features enabling cost effective, easy integration.









Features And Benefits
Easy Integration
XG 1700 has many control and indication signals such as shutdown, constant voltage (CV) vs. constant current (CC) mode indication, OVP, OCP, OTP, and so on. In addition, the logical-high or -low is free selectable. Thus enabling the XG 1700 to replace existing power supplies with little or no system engineering required.



Free Selectable Analog Control Range
Most DC power supplies provide a 0 to 5 or 0 to 10 V analog control range to control the DC output from zero to full DC output range. With the XG 1700, the analog control range is free selectable starting at 0V to an upper range between 2V and 10V. In other words, the analog programming interface range is freely adjustable.



Auxiliary DC Output Channels with Control
In many ATE systems one or more low power, fixed voltage supplies are needed to provide electrical power for any periphery within the ATE cabinet. For this purpose, the XG 1700 provides two standard auxiliary DC output channels. Both auxiliary power channels are controllable directly from the front-panel or through SCPI commands. With these channels, it is possible to drive output-disconnect or polarity-reversal relays, without needing a complicated computer controlled relay board.



DC-Waveforms Through Internal Sequencing
To allow for extremely fast programming, sequences can be programmed into and stored in memory using standard SCPI commands through USB, RS-232/485, LXI or GPIB.



Variable Fan Speed COntrol
The XG 1700’s innovative approach to fan speed is determined by internal heat sink temperature. This allows the fans to adjust to a constant optimal speed when the output of the supply is being pulsed. This also reduces noise and increases fan life.



Power Saving Standby Mode
When the XG 1700 has been in an idle state, the supply can go into â€œsleep mode”, much like a computer monitor. This will allow the user to save energy and minimize lab noise. Since an XG 1700 left in sleep mode is still â€œon” the user will have quicker access to an enabled output.



Output Auto Start Mode (Auto Restart)
The Auto Start mode establishes the state of the output of the power supply after recovery from a complete power cycle (all front panel LEDs are not illuminated), or after recovery from a PC failure or reboot. If Auto Start mode is set to On, the power supply output will return to its previous value. Also, after the loss of any remote digital control, the XG unit will remain active in its last programmed setting and will not disrupt any test process.



Auxiliary Auto Start Mode
The Auxiliary Auto Start mode determines the state of the auxiliary output after a complete power cycle (all front panel LEDS are not illuminated). With Auxiliary Auto Start mode turned to On, the auxiliary output will be activated after the power supply is powered up again.



Foldback Mode
Foldback mode is used to disable the output when a transition is made between the operating modes. The power supply will turn off/disable the output and lock in foldback mode after a specified delay if the power supply transitions into CV mode or into CC mode, depending on the foldback mode settings. This feature is particularly useful for protecting current or voltage sensitive loads. Foldback can be set to trigger a switch when transitioning from CV to CC mode or from CC to CV mode.





Sorensen Power Supply DC PowerEnergy Absorber
Sorensen Power Supply DC PowerEnergy Absorber
Product OverviewThe Energy Absorber Test System includes power supplies and a regenerative energy absorber with a rating of 400VDC at ±150A. The system consists of DC p
Sorensen Power Supply Solar Array Simulator
Sorensen Power Supply Solar Array Simulator
Product OverviewA spacecraft solar array is subjected to large temperature excursions, varying insolation (the amount of sunlight falling on the array), mechanical changes and agi
Sorensen Power Supply Sorensen XFR Series
Sorensen Power Supply Sorensen XFR Series
Product Overview XFR is the smart choice for research, product development and production test applications such as R&D, magnet control, product design, ATE, process control,&
Sorensen Power Supply High-Current Power System
Sorensen Power Supply High-Current Power System
Industry : science research Application : Science Description : Super-conducting wire experiments and contact testing Function : Provides 15,000A DC at 5V DC in current mode F
Sorensen Power Supply RP Series
Sorensen Power Supply (TW) Series
Sorensen Power Supply (TW) Series
Product OverviewThe Elgar TrueWave (TW) is designed for testing today's complex electronics, including avionics and commercial applications requiring DC and sine wave testing. The&nb
Sorensen Power Supply Elgar GUPS Series
Sorensen Power Supply Elgar GUPS Series
Measurement that can be made:
Sorensen Power Supply Power, Special Test Equipment
Sorensen Power Supply Power, Special Test Equipment
Product OverviewThe Elgar Power Special Test Equipment (PSTE) provides programmable DC power, and programmable loading, to the electrical systems of satellites for system functional&
Sorensen Power Supply Compliance Test System
Sorensen Power Supply Compliance Test System
The Elgar TrueWave (TW) is designed for testing today's complex electronics, including avionics and commercial applications requiring DC and sine wave testing. The TW is ideal