EATON 9155 UPS K40812000000000

EATON 9155 UPS K40812000000000
share

Specifications:
Rating (VA/Watts) 8000/7200
Diagnostics Full system self-test at startup
UPS Bypass Automatic on overload or UPS failure
Dimensions (H x W x D, inches) 47.8 x 12 x 33.7
Weight (lbs) 590
Frequency 50/60 Hz (45 to 65 Hz)
Frequency Range 45 to 65 Hz
Input Power Factor P.F >0.99 typical, >0.96 frequency converter
Electrical Output
100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement
Output Receptacles
(1) PDM
On Utility Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
On Battery Voltage Regulation Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change
Overload Capacity 150% for 5 sec / 125% for 1 min (online), 110% for 10 min
Voltage Wave Shape (On Battery) Sine Wave
Transfer Time 0 ms

EATON 9355 UPS KB2013200000010
EATON 9355 UPS KB2013200000010
Specifications:General Color BlackForm Factor TowerAttributes Double conversion onlinePower Battery Run Time (max) 18 minute(s)Power Provided 20000 VAPower Provided 18000 watt(s)Power Provided 220 VSurge Suppression StandardActual Weight 1160.00 lb(s)
EATON Preassembled BladeUPS ZP23110XXXXX000
EATON Preassembled BladeUPS ZP23110XXXXX000
Specifications:Color BlackCable Entry BottomAvailable U Space 30URack Doors Front - One piece locking mesh doorRear - Split locking mesh doorsUPS Bypass Automatic on overload or UPS failureDimensions (H x W x D, inches) 81.0 x 24.0 x 42.0Dimensions (H x W x D, mm) 2058 x 610 x 1067Weight (kg) 306Inp
EATON 9130 Tower UPS PW9130G2000T-XLEU
EATON 9130 Tower UPS PW9130G2000T-XLEU
Specifications:Rating (VA/Watts) 2000/1800Diagnostics Full system self-testUPS Bypass Automatic bypassDimensions (H x W x D, inches) 12.8 x 8.4 x 16.1Weight (lbs) 76.1Nominal Voltage 208 VACFrequency 50/60 HzFrequency Range 45–65 HzNominal Current 9.6 ABreaker Ratings 10AElectrical OutputOn Utilit
EATON Preassembled BladeUPS ZP225150000X000
EATON Preassembled BladeUPS ZP225150000X000
Specifications:Color BlackCable Entry TopAvailable U Space 6URack Doors Front - One piece locking mesh doorRear - Split locking mesh doorsUPS Bypass Automatic on overload or UPS failureDimensions (H x W x D, inches) 81.0 x 24.0 x 42.0Dimensions (H x W x D, mm) 2058 x 610 x 1067Weight (kg) 890Input V
EATON Preassembled BladeUPS ZP222100XXXX000
EATON Preassembled BladeUPS ZP222100XXXX000
Specifications:Color BlackCable Entry TopAvailable U Space 24URack Doors Front - One piece locking mesh doorRear - Split locking mesh doorsUPS Bypass Automatic on overload or UPS failureDimensions (H x W x D, inches) 81.0 x 24.0 x 42.0Dimensions (H x W x D, mm) 2058 x 610 x 1067Weight (kg) 451Input
EATON 9315 UPS 200-300 kVA
EATON 9315 UPS 200-300 kVA
Describtions:The Eaton 9315 UPS provides proven backup power and scalable battery runtimes for large data centers, facilities and other critical applications. The 9315 UPS can be paralleled for both redundancy and capacity using Powerware Hot Snyc technology.
EATON EX UPS PULSI1500R-XL2U
EATON EX UPS PULSI1500R-XL2U
Specifications:Rating (VA/Watts) 1500/1350Dimensions (H x W x D, inches) 3.46 x 17.25 x 19Weight (lbs) 45Nominal Voltage 230 VACFrequency 50/60 HzInput frequency Range Without Using Batteries 40 to 70 HzElectrical OutputOutput Receptacles (6) IEC-320-C13Power Factor 0.9Load Segments 2 independent gr
EATON 9170+ UPS Technical Specs PW6S9K-PD
EATON 9170+ UPS Technical Specs PW6S9K-PD
Specifications:Technical InformationPlug/Connector Type HardwiredReceptacles 2 x NEMA L14-30R2 x NEMA L6-30R12 x NEMA 5-20RPower DescriptionLoad Capacity 9 kVA/6.30 kWInput Voltage 110 V AC220 V ACInput Voltage Range 120 V AC208 V AC240 V ACOutput Voltage 120 V AC208 V AC240 V ACFrequency 50 Hz Inpu
EATON 9130 Tower UPS PW9130i1000T-XL
EATON 9130 Tower UPS PW9130i1000T-XL
Specifications:Rating (VA/Watts) 1000/900Diagnostics Full system self-testEcoControl NULLUPS Bypass Automatic bypassDimensions (H x W x D, inches) 9.1 x 6.3 x 15Weight (lbs) 32Nominal Voltage 230 VACFrequency 50/60 HzFrequency Range 45–65 HzNominal Current 4.3 ABreaker Ratings 10AElectrical Output
EATON Preassembled BladeUPS ZP2161000000000
EATON Preassembled BladeUPS ZP2161000000000
Specifications:Configuration Preassembled in S-Series RackColor BlackCable Entry BottomAvailable U Space NoneUPS Bypass Automatic on overload or UPS failureDimensions (H x W x D, inches) 81.0 x 24.0 x 42.0Dimensions (H x W x D, mm) 2058 x 610 x 1067Weight (kg) 1036Input Voltage Range 180 to 265VNomi